tools

  • The set includes 4/5/6/8/10mm wood drills In a plastic box
  • Technical data: Max voltage between contacts and ground is CAT III, 600V. Fuse: 200mA, 250 V 2 pcs. Max numerical reading: 1999, 3½. Polarity indication "-"; negative polarity. When the limit value of the measuring range is exceeded: "1" is shown on the display. Polarity: Only ``-'' on the display. Low battery indication: the battery symbol flashes. Battery: 9 V. Operating temperature: 0...+40 °C. Storage temperature: -10...+50 °C. Dimensions: 138x69x31 mm. Weight: about 170g.
    The accuracy of the meter is calibrated for approximately one year of use at a temperature of 16-28 °C and a relative humidity of 80%.
  • Technical data: Max voltage between contacts and ground is CAT III, 600V. Fuse: 200mA, 250 V 2 pcs. Max numerical reading: 1999, 3½. Polarity indication "-"; negative polarity. When the limit value of the measuring range is exceeded: "1" is shown on the display. Polarity: Only ``-'' on the display. Low battery indication: the battery symbol flashes. Battery: 9 V. Operating temperature: 0...+40 °C. Storage temperature: -10...+50 °C. Dimensions: 138x69x31 mm. Weight: about 170g.
    The accuracy of the meter is calibrated for approximately one year of use at a temperature of 16-28 °C and a relative humidity of 80%
  • With the detector, it is possible to identify wooden frames, metal and live cables inside the wall or floor. It is intended for use in construction, mounting furniture to the wall, etc.
  • Electric moisture meter e. hygrometer. Two sharp-tipped metal sensors are pressed against the material, the device's LCD screen displays the wood moisture indicator in percent. Measuring range 5...42% (+/-1%). Operating temperature 0...+40C. Battery 1x9V is included. NB! Surface treatment of wood is not recommended if the humidity is higher than 18%.
  • Technical specifications: Max voltage between contacts and ground is CAT III, 250V. Max numerical reading: 1999, 3½. Polarity indication "-"; negative polarity. When the limit value of the measuring range is exceeded: "1" is shown on the display. Polarity: Only ``-'' on the display. Low battery indication: the battery symbol flashes. Test battery: 9 V included. Operating temperature: 0...+40C. Storage temperature: -10...+50C. Dimensions: 115x65x31 mm. Weight: about 170g. Voltage AC V: 200mV - 250V Voltage DC V: 200V - 250V DC current: 200mA - 10A Resistance: 200 - 2M ohms
  • DC and AC current clamps Intensity AC (2A / 20A / 200A / 400A) Voltage AC/DC (200mV / 2V / 20V / 200V / 600V) resistance (200? / 2k? / 20k? / 200k? / 2M? / 20M?) diode test continuity test Operating conditions: 0...+40C, storage conditions -10...+50C. The backlight of the LCD screen allows you to read the information on the screen even in poor light. The set includes batteries 2xAAA, measuring cables, cloth case.
  • The set includes 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28 30 and 32mm
  • The set includes 6, 10, 13, 16, 19, 22, 25, 32 mm, 300 mm drill extension and hex key..

Title

Go to Top